The SI5335A-B07905-GMR has a total of 20 pins. The pin configuration is as follows:
| Pin Number | Pin Name | Description | |------------|----------|-------------| | 1 | VDDO | Output Power Supply Voltage | | 2 | GND | Ground | | 3 | XAXB | Differential Clock Input | | 4 | XAXA | Differential Clock Input | | 5 | XBXB | Differential Clock Input | | 6 | XBXC | Differential Clock Input | | 7 | XBXA | Differential Clock Input | | 8 | XAXC | Differential Clock Input | | 9 | SDA | I2C Serial Data Input | | 10 | SCL | I2C Serial Clock Input | | 11 | VDDI | Digital Power Supply Voltage | | 12 | GND | Ground | | 13 | CLKOUT0 | Output Clock 0 | | 14 | CLKOUT1 | Output Clock 1 | | 15 | CLKOUT2 | Output Clock 2 | | 16 | CLKOUT3 | Output Clock 3 | | 17 | CLKOUT4 | Output Clock 4 | | 18 | CLKOUT5 | Output Clock 5 | | 19 | GND | Ground | | 20 | VDDO | Output Power Supply Voltage |
Advantages: - Wide range of output frequencies - Flexible input/output options - Low phase jitter - High-frequency performance
Disadvantages: - Limited to clock generation and multiplication functions - Requires external power supply
The SI5335A-B07905-GMR is suitable for applications that require precise clock generation and multiplication. It can be used in various industries, including telecommunications, networking, data centers, and consumer electronics.
The SI5335A-B07905-GMR utilizes a combination of PLL (Phase-Locked Loop) and VCO (Voltage-Controlled Oscillator) techniques to generate and multiply clock signals. The input clock is multiplied by a programmable factor to produce the desired output frequency.
The SI5335A-B07905-GMR can be used in the following applications: 1. Telecommunications infrastructure equipment 2. Network switches and routers 3. Data center servers and storage systems 4. High-speed communication interfaces 5. Test and measurement instruments
Some alternative models to the SI5335A-B07905-GMR are: 1. SI5338A-B07905-GMR 2. SI5341B-B07905-GMR 3. SI5368A-B07905-GMR 4. SI5389A-B07905-GMR 5. SI5395B-B07905-GMR
Q: What is the maximum output frequency of the SI5335A-B07905-GMR? A: The maximum output frequency is 710MHz.
Q: Can I use a single-ended clock input with this device? A: No, the SI5335A-B07905-GMR requires differential clock inputs.
Q: What is the typical phase jitter of this clock generator? A: The typical phase jitter is less than 0.5 ps RMS.
Q: Does this IC require an external crystal oscillator? A: No, the SI5335A-B07905-GMR has an integrated VCO.
Q: What is the operating