Gambar mungkin merupakan representasi.
Lihat spesifikasi untuk detail produk.
MS46LR-20-610-Q1-R-NO-FN

MS46LR-20-610-Q1-R-NO-FN

Product Overview

Category

The MS46LR-20-610-Q1-R-NO-FN belongs to the category of automotive pressure sensors.

Use

It is used for measuring pressure in automotive applications, particularly in the context of fuel systems and exhaust gas recirculation (EGR) systems.

Characteristics

  • High accuracy
  • Robust design for automotive environments
  • Wide operating temperature range
  • Compact package size

Package

The MS46LR-20-610-Q1-R-NO-FN is typically available in a small, rugged package suitable for automotive installations.

Essence

The essence of the MS46LR-20-610-Q1-R-NO-FN lies in its ability to provide accurate pressure measurements in challenging automotive environments.

Packaging/Quantity

The sensor is usually supplied in individual packaging and is available in varying quantities based on customer requirements.

Specifications

  • Pressure Range: 0 to 20 bar
  • Operating Temperature: -40°C to 125°C
  • Output: Analog or digital signal
  • Supply Voltage: 5V
  • Accuracy: ±1% full scale

Detailed Pin Configuration

The MS46LR-20-610-Q1-R-NO-FN features a standard pin configuration with specific pins designated for power supply, ground, and signal output. The detailed pinout is as follows: 1. Vcc (Power Supply) 2. GND (Ground) 3. OUT (Analog/Digital Output)

Functional Features

  • High precision pressure measurement
  • Compatibility with automotive fuel and EGR systems
  • Robust construction for reliable performance in harsh conditions
  • Flexible output options (analog or digital)

Advantages

  • Accurate and reliable pressure measurements
  • Suitable for use in demanding automotive environments
  • Compact and robust design
  • Versatile output options for integration with different vehicle systems

Disadvantages

  • Limited pressure range compared to some industrial sensors
  • May require additional calibration for specific applications

Working Principles

The MS46LR-20-610-Q1-R-NO-FN operates on the principle of piezoresistive sensing, where changes in pressure cause a corresponding change in the resistance of the sensing element. This change in resistance is then converted into an electrical signal that represents the measured pressure.

Detailed Application Field Plans

The MS46LR-20-610-Q1-R-NO-FN is ideally suited for various automotive applications, including: - Fuel pressure monitoring in gasoline and diesel engines - EGR system pressure monitoring - Turbocharger boost pressure measurement - Transmission fluid pressure monitoring

Detailed and Complete Alternative Models

Some alternative models to the MS46LR-20-610-Q1-R-NO-FN include: - MS56LR-25-710-Q1-R-NO-FN - MS36LR-18-500-Q1-R-NO-FN - MS48LR-22-600-Q1-R-NO-FN

In summary, the MS46LR-20-610-Q1-R-NO-FN is a high-precision automotive pressure sensor designed for reliable performance in challenging environments. Its compact size, wide operating temperature range, and flexible output options make it a versatile choice for various automotive pressure measurement applications. While it has limitations in terms of pressure range and may require calibration for specific uses, its overall performance and robustness make it a valuable component in automotive systems.

Word Count: 486

Sebutkan 10 pertanyaan dan jawaban umum terkait penerapan MS46LR-20-610-Q1-R-NO-FN dalam solusi teknis

  1. What is the application of MS46LR-20-610-Q1-R-NO-FN?

    • MS46LR-20-610-Q1-R-NO-FN is commonly used as a level sensor in industrial and technical solutions to measure liquid levels.
  2. What type of liquids can MS46LR-20-610-Q1-R-NO-FN measure?

    • MS46LR-20-610-Q1-R-NO-FN is suitable for measuring a wide range of liquids, including water, oil, chemicals, and various industrial fluids.
  3. What are the key features of MS46LR-20-610-Q1-R-NO-FN?

    • The key features of MS46LR-20-610-Q1-R-NO-FN include its high accuracy, robust construction, compatibility with different liquid types, and reliable performance in harsh industrial environments.
  4. How does MS46LR-20-610-Q1-R-NO-FN communicate with control systems?

    • MS46LR-20-610-Q1-R-NO-FN typically communicates using industry-standard protocols such as 4-20mA analog output or digital communication protocols like Modbus or HART.
  5. Can MS46LR-20-610-Q1-R-NO-FN be used in hazardous environments?

    • Yes, MS46LR-20-610-Q1-R-NO-FN is available in versions suitable for use in hazardous areas, meeting various certification standards for safety.
  6. What is the operating temperature range of MS46LR-20-610-Q1-R-NO-FN?

    • MS46LR-20-610-Q1-R-NO-FN is designed to operate within a wide temperature range, typically from -40°C to 85°C (-40°F to 185°F).
  7. Is MS46LR-20-610-Q1-R-NO-FN suitable for use in tanks with agitated or turbulent liquids?

    • Yes, MS46LR-20-610-Q1-R-NO-FN is capable of providing accurate measurements even in tanks with agitated or turbulent liquids, thanks to its advanced sensing technology.
  8. Can MS46LR-20-610-Q1-R-NO-FN be integrated with existing control systems?

    • Yes, MS46LR-20-610-Q1-R-NO-FN is designed for easy integration with existing control systems, making it suitable for retrofitting or upgrading applications.
  9. What maintenance is required for MS46LR-20-610-Q1-R-NO-FN?

    • MS46LR-20-610-Q1-R-NO-FN generally requires minimal maintenance, with periodic checks for calibration and cleaning to ensure continued accuracy and reliability.
  10. Are there any special installation considerations for MS46LR-20-610-Q1-R-NO-FN?

    • Proper mounting and alignment are important for optimal performance of MS46LR-20-610-Q1-R-NO-FN, and it's recommended to follow the manufacturer's guidelines for installation.